ST40F-ESB
ST50F-ESB
STRIDER ESSENTIAL SERIES
High efficiency with 80 PLUS Bronze certification
24/7 continuous power output with 40 C operating temperature
Class-leading single +12V rail
Multiple protection circuitry
Silent running 120mm fan with 18dBA
PCI-E connectors support
Active PFC
Power for everything you need
o
Seitenansicht 0
1 2 3 4 5 6 ... 11 12

Inhaltsverzeichnis

Seite 1 - ST50F-ESB

ST40F-ESBST50F-ESBSTRIDER ESSENTIAL SERIESHigh efficiency with 80 PLUS Bronze certification24/7 continuous power output with 40 C operating temperatur

Seite 2

07A TTL compatible signal for the purpose of initiating an orderly start-up procedure under normal input operating conditions. During power up, this s

Seite 3

08The MTBF of the power should be 50,000 hours min.10. MTBF The product shall meet requirement for EN61000-3-2 & EN61000-3-3 :2003 standard of cla

Seite 6 - 3.4 Rise Time

The following manual and guides were carefully prepared by the SilverStone engineering team to help you maximize the potential of your SilverStone pro

Seite 7 - 3.9 Capacitive Load

SPECIFICATIONSilverStone Strider EssentialST50F-ESBST40F-ESBATX12V 2.3 Switching Power SupplyWith Active PFC80 Plus BronzePS/2011.1 Scope2.1 Input Vol

Seite 8 - 5. Start Stability

022.3 Max. Input AC CurrentThe power supply must meet inrush requirements for any rated AC voltage, during turn on at any phase of AC voltage, during

Seite 9 - 7. Conducted EMI

03SST-ST40F-ESBNOTE:Noise test should be measured with 20 MHz bandwidth frequency oscilloscope. The output terminal shall add a tantalum capacitor of

Seite 10 - 9. Power Good Signal

043.5 Hold-up TimeDC +5V output maintains at least 16mS ,after power off , under 230V/50Hz 75%Load condition.3.6 5VSB5VSB is requierd for the impleme

Seite 11 - 11. Burn-In

054.1 Input ProtectionIn primary circuit of the power supply , a protected fuse is inserted. Only internal fault of the power supply will cause the fu

Seite 12 - G11222300

066.1 Temperature and Humidity6.2 Altitude6.1.1 OperatingTemperature 0 to 40 C Relative Humidity 20 to 90 %6.1.2 StorageTemperature -40 to 70 CRel